MC Interlocked Armored Cable 3 Conductors EPR AIA/PVC UL MC/MV-105 15kV-133%
MC Interlocked Armored Cable 3 Conductors EPR AIA/PVC UL MC/MV-105 5kV-133% 8kV-100%
Get A Quote
Product Inquiry
Product Picture
Product name
MC Interlocked Armored Cable 3 Conductors EPR AIA/PVC UL MC/MV-105 15kV-133%
MC Interlocked Armored Cable 3 Conductors EPR AIA/PVC UL MC/MV-105 5kV-133% 8kV-100%
OVERVIEW
SPECIFICATIONS
CONSTRUCTION
PARAMETER
LEAVE YOUR FEEDBACK
Features
Rated at 105ºC wet or dry. Excellent heat and moisture resistance. Outstanding corona resistance. Flexible for easy handling. High dielectric strength. Low moisture absorption. Electrically stable under stress. Low dielectric loss. Chemical- and radiation-resistant. Excellent crush resistance. Cost-effective alternative to installations in conduit. Meets cold bend test at -25ºC.
Applications:
For use in wet or dry locations, indoors or outdoors, in exposed or concealed work. May be used in cable trays or on approved support in protected areas. Permitted for use in Class I; Class II, Division 2; and Class III, Divisions 1 and 2 hazardous locations per the NEC. Ideal for use in commercial, industrial and utility applications where space is limited and reliability, maximum performance, ease of installation and fire resistance are important.
Compliances
Industry: UL 1072. ICEA S-93-639/NEMA WC74. AEIC CS8. UL Type MV-105. UL Type MC.
Flame Test: IEEE 383 (70,000 BTU/hr). UL 1581 (70,000 BTU/hr). IEEE 1202 (70,000 BTU/hr) CSA FT4. ICEA T-29-520 (210,000 BTU/hr). ICEA T-30-520 (210,000 BTU/hr).
Specifications
UV Resistance
UV Resistance
Flame Retardant
Flame Retardant
Fire Resistance
Fire Resistance
construction
Conductor:
4 AWG through 1000 kcmil bare copper compact, Class B strand.
Extruded Strand Shield (ESS):
Thermoset semi-conducting stress-control layer over conductor.
Insulation:
Ethylene Propylene Rubber (EPR) insulation, colored to contrast with black conducting layers.
Extruded Insulation Shield (EIS):
Thermoset semi-conducting polymeric layer, free stripping from insulation.
Shield:
5 mil annealed copper tape with a minimum 25% overlap.
Ground:
Annealed bare copper Class B stranding per ASTM B8.
Armor:
Aluminum Interlocked Armor (AIA)
Jacket:
Flame-retardant moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow.
PARAMETER
UL MC/MV-105 5kV-133% 8kV-100%


Size (AWG
or
kcmil)



No. of
Strands



Insul. Thick. (Mils)

Nom. Diam. Over Armor
(Inches)



PVC Jkt.
Thick. (Mils)

Nom. Diam. Over PVC Jkt.
(Inches)
Copper Phase Conductors

Copper Grounding Conductor (AWG)
Weight
(lbs./1000 ft.)


Ampacity*


Ampacity**

Alum. Armor

Steel Armor


Copper
4 7 115 1.44 50 1.54 6 1360 1745 619 100 115
2 7 115 1.57 60 1.70 6 1775 2160 864 135 154
1 19 115 1.65 60 1.78 4 2055 2475 1074 155 180
1/0 19 115 1.78 60 1.91 4 2335 2745 1298 185 205
2/0 19 115 1.88 60 2.01 4 2705 3130 1566 210 240
3/0 19 115 1.99 60 2.12 3 2920 3375 1918 245 280
4/0 19 115 2.11 60 2.24 3 3730 4290 2360 285 320
250 37 115 2.23 60 2.36 3 4200 4770 2735 315 355
350 37 115 2.46 75 2.62 2 5590 6220 3736 390 440
500 37 115 2.77 75 2.93 1 7490 8210 5222 475 545
750 61 115 3.18 85 3.37 1/0 10385 11195 7684 585 685
1000 61 115 3.50 85 3.69 1/0 13345 14150 10057 660 790
*AMPACITY for cables installed in uncovered cable tray without maintained spacing: 105˚C conductor temperature, 40˚C ambient.
**AMPACITY for cables installed in uncovered cable tray with maintained spacing of one cable diameter: 105˚C conductor temperature, 40˚C ambient. For other installation conditions refer to the NEC.